TFC400-63 Series Programmable 3 Phase 115V 400Hz AC Power Source 1.5kVA 3kVA 6kVA to 800kVA

TFC400-63 Series Programmable 3 Phase 115V 400Hz AC Power Source 1.5kVA 3kVA 6kVA to 800kVA

  • Programmable 3 phase 115V 400Hz AC power source
  • Rated voltage 115Vac, adjustable range 10V~150V
  • Rated frequency 400Hz, adjustable range 320.0Hz ~480.0Hz
  • Capacity 1.5kVA 3kVA 6kVA to 800kVA
  • Frequency stability 0.01%
  • Harmonic distortion 2%
  • Voltage stability 1%
  • RS232 or RS485 interface, support ModBus-RTU
  • Optional DC 0-5V or 0-10V analog control
  • Optional output voltage range 0~1000V
  • Optional output frequency range 200Hz~2500Hz

TFC400-63 series is programmable 3 phase 115Vac 400Hz AC power source that provides rated output 115Vac 400Hz in three phase wires (L1+L2+L2). They are designed for high-power testing of aircraft, vessels, and military equipments that generally operates at 115Vac 400Hz. It features low magnetic leakage, good reliability, fast response and high efficiency

The output voltage is rated at 115V and is adjustable from 10V to 150V in single range. It can be customized to a dual range output: low range150V and high range 300V. The output frequency is rated at 400Hz and is adjustable from 320Hz to 480Hz. It can be customized to 500Hz or higher frequency, max 2500Hz.

The 3 phase 115V 400Hz AC power source can be connected to unbalanced loads and each phase used as a single phase 400Hz supply.

Product Parameters

TFC400-63 Series Three Phase 400Hz AC Power Source

ModelCapacityMax. Current @115VAC InputN.W. (kg)G.W. (kg)Dimension (mm)
TFC400-6301.51.5KVA4.3A1P 220Vac3040450W*176H*500D
TFC400-63033KVA8.6A3P 380Vac4050450W*176H*500D
TFC400-63066KVA17.3A3P 380Vac150175500W*900H*680D
TFC400-631010KVA29A3P 380Vac170200500W*900H*680D
TFC400-631515KVA43A3P 380Vac200240500W*900H*680D
TFC400-632020KVA58A3P 380Vac260300590W*1100H*800D
TFC400-633030KVA86A3P 380Vac300360590W*1100H*800D
TFC400-634545KVA130A3P 380Vac400450720W*1220H*1080D
TFC400-636060KVA173A3P 380Vac500580720W*1220H*1080D
TFC400-637575KVA217A3P 380Vac530610750W*1300H*1382D
TFC400-639090KVA260A3P 380Vac650730750W*1300H*1382D
TFC400-63100100KVA289A3P 380Vac7008201380W*1580H*870D
TFC400-63120120KVA347A3P 380Vac8009001380W*1580H*870D
TFC400-63150150KVA434A3P 380Vac90010001380W*1580H*870D
TFC400-63180180KVA521A3P 380Vac120013201650W*1800H*1150D
TFC400-63200200KVA579A3P 380Vac130014201650W*1800H*1150D
TFC400-63250250KVA724A3P 380Vac150016201650W*1800H*1150D
TFC400-63300300KVA869A3P 380Vac8009002000W*1700H*1080D
TFC400-63400400KVA1159A3P 380Vac100011502000W*1700H*1080D
TFC400-63500500KVA1449A3P 380Vac180020002700W*2100H*1100D
TFC400-63600600KVA1739A3P 380Vac200022002700W*2100H*1100D
TFC400-63750750KVA2173A3P 380Vac300035003200W*2200H*1400D
More models are available at request.

For the purpose of product improvement, specifications are subject to change without prior notice.

Why Choose Us.

  • With years of industry knowledge, we bring unparalleled expertise to every project.
  • Our rigorous standards ensure top-notch quality in all our products.
  • Constantly striving for new and improved solutions, we never stop innovating.
  • Tailoring our services to your unique needs, we ensure complete satisfaction.
  • Experience excellence with our dedicated support and customer-focused approach.

Frequently Asked Questions

A DC power supply is to supply voltage and current in constant voltage (CV) or constant current (CC) mode within the rated output range. Such working characteristics is called a constant voltage/constant current automatic cross-over type. This permits continuous transition from constant current to constant voltage modes in response to the load change. The intersection of constant voltage and constant current modes is called the crossover point. Below figure shows the relationship between this crossover point and the load.

In CV mode, a regulated output voltage is provided. The output voltage remains constant as the load increases while the output current changes in response to the load changes, up till the present current limit point is reached. At that point, the output current becomes constant and the output voltage drops in proportion to the further increases in load.

Similarly, in CC mode, crossover from the CC to CV mode automatically occurs from a decrease in the load. A regulated output current is provided. The output current remains constant as the load decreases while the output voltage changes in response to the load changes.

A power supply with CV and CC operation mode can be operated in only one mode according to load situation. The power supply is in CV mode when the actual load is over the preset load capacity; and the power supply is in CC mode when the actual load is below the preset load capacity.

When the power supply is connected to a big capacitive load, it always causes increase to the output voltage in a power supply. The output voltage may make fast increase to the Over Voltage Protection point. It may also cause slow decrease when the output voltage is turned down.

To solve this problem, connect a power resistor in parallel to the output terminals of the power supply; at the same time, connect a diode in serial between output terminals and the load.

When an inductive load is connected to the power supply, it will cause a reverse polarity induction electric motive force when the power supply is turned on or off, or when preset the output voltage. The pulse noise caused by an inductive load will also affect the power supply, especially when the pulse noise has the same polarity with the output of power supply.

To avoid effect or damage to the power supply, connect a diode in serial between the output terminals of power supply and the load; at the same time, connect a power resistor and a capacitor in parallel to the load to make a R-C snubbed circuit, which will significantly restraint generation of the noise.

When use the power supply to charge a battery, such as accumulator and ni-mh battery, the recommended protection measures is to connect a diode between the power supply and the battery. When the output electrolytic capacitor of the power supply is charged, connecting a load (battery) may cause sparks. This is normal. After the two of them get to equal voltage, the sparks will disappear.

Even if the peak current of a pulse load, such as motor, bulb, DC-DC or DC-AC converter module, does not exceed the rated current of the power supply, it will also cause voltage drop or instability to the output.

A basic solution is to connect a inductor in serial between the power supply and the load. Or, choose a power supply with higher rated current.

If the pulse circuit has a small pulse width or low peak current, another solution is to connect a capacitor with large capacity. A reference to choose capacity of a capacity is: 1000uF capacity to a 1A current.

When the power supply is connected to a load that will cause reverse polarity current to the power supply output, the output voltage will increase, because the power supply cannot absorb the reverse polarity current from the load.

A solution is to connect a diode in serial between the output terminal and the load; at the same time, connect a discharge resistor in parallel to the load to absorb the reverse polarity current. When the reverse polarity current is a peak surge, connect the large electrolytic capacitor in parallel to the two ends of the load.

Get Quote Now!

Welcome to discuss your purchasing requirements with our customer service.

    Get The
    Catalogue
    Document

    From more than 10 years experiences in OEM & ODM services, our sales team and technical team are always available to check and discuss your requirement details.Whether you’re looking for reliable DC motors to enhance precision in your devices or powerful AC motors for robust industrial applications, we have you covered.

    en_USEnglish