In the range of 1kV to 12kV programmable high voltage DC power supplies, TWINTEX a wide range of products in power levels from 600W to 8kW, customized to 75kW max.

Key features

2U / 3U rack mount

Power level 600W 1200W 2400W 3kW 4kW 5kW 6kW 8kW

High stability

Continuous operation for 24×7

Positive polarity 1kV 1.2kV 1.5kV 2kV 3kV 4kV 5kV 6kV 8kV 10kV 12kV

Options of negative polarity -1kV -1.2kV -1.5kV -2kV -3kV -4kV -5kV -6kV -8kV -10kV -12kV

Adjustable voltage rise time 1s to 9999s

1V resolution

0.1% voltage regulation

0.1% voltage ripple

The 1kV to 12kV programmable high voltage DC power supplies are designed for both laboratory and industrial applications, such as:

Insulation breakdown testing

High voltage capacitor charging / reforming

High voltage inverter testing

Automatic test equipment (ATE)

Power high voltage photovoltaic devices

Power semiconductor devices such as diodes, power MOSFET, IGBT

TWINTEX provides custom solutions for high power and high voltage applications from 1kV to 12kV, for example:

5000V 10A 50kW high voltage power supply

10kV 1A 10kW high voltage power supply

10kV 2A 20kW high voltage power supply

10kV 5A 50kW high voltage power supply

12kV 1A 12kW high voltage power supply

3000V 25A 75kW high voltage power supply

PCH 600W Compact Programmable High Voltage DC Power Supply 1000V 1200V 1500V 2000V 3000V

PCH 1200W Compact 1200V 1A Programmable High Voltage Power Supply 1000V 1500V 2000V 3000V

PCH 600W Programmable High Voltage Power Supply 1kV to 10kV 12kV

PCH 1200W 1kV 1.2kV 1.5kV 2kV 3kV Programmable High-voltage DC Power Supply up to 10kV 12kV

PCH 2400W 10kV High Voltage Power Supply 1000V to 12kV

PCH 3kW 1000V 3A DC Power Supply 3000V 1A up to 6kV 10kV 12kV

PCH 4kW 4000V 1A DC High Voltage Power Source 1000V 4A 2000V 2A to 8kV 12kV

PCH 5kW 1kV to 10kV 12kV Programmable High Voltage HV DC Power Supply with Parallel Option

Let The World Know About Twintex

Twintex Instrument Ltd. was established in 1998.With honesty, innovation and continuation as the core of enterprise cultural, Twintex has been gradually developed into a test & measurement instruments manufacturer, products including oscilloscope, waveform/function generator, DC power supply, AC power supply, multimeter, LCR meter and other general purpose test & measurement instruments.

Application

Frequently Asked Questions

A DC power supply is to supply voltage and current in constant voltage (CV) or constant current (CC) mode within the rated output range. Such working characteristics is called a constant voltage/constant current automatic cross-over type. This permits continuous transition from constant current to constant voltage modes in response to the load change. The intersection of constant voltage and constant current modes is called the crossover point. Below figure shows the relationship between this crossover point and the load.

In CV mode, a regulated output voltage is provided. The output voltage remains constant as the load increases while the output current changes in response to the load changes, up till the present current limit point is reached. At that point, the output current becomes constant and the output voltage drops in proportion to the further increases in load.

Similarly, in CC mode, crossover from the CC to CV mode automatically occurs from a decrease in the load. A regulated output current is provided. The output current remains constant as the load decreases while the output voltage changes in response to the load changes.

A power supply with CV and CC operation mode can be operated in only one mode according to load situation. The power supply is in CV mode when the actual load is over the preset load capacity; and the power supply is in CC mode when the actual load is below the preset load capacity.

When the power supply is connected to a big capacitive load, it always causes increase to the output voltage in a power supply. The output voltage may make fast increase to the Over Voltage Protection point. It may also cause slow decrease when the output voltage is turned down.

To solve this problem, connect a power resistor in parallel to the output terminals of the power supply; at the same time, connect a diode in serial between output terminals and the load.

When an inductive load is connected to the power supply, it will cause a reverse polarity induction electric motive force when the power supply is turned on or off, or when preset the output voltage. The pulse noise caused by an inductive load will also affect the power supply, especially when the pulse noise has the same polarity with the output of power supply.

To avoid effect or damage to the power supply, connect a diode in serial between the output terminals of power supply and the load; at the same time, connect a power resistor and a capacitor in parallel to the load to make a R-C snubbed circuit, which will significantly restraint generation of the noise.

When use the power supply to charge a battery, such as accumulator and ni-mh battery, the recommended protection measures is to connect a diode between the power supply and the battery. When the output electrolytic capacitor of the power supply is charged, connecting a load (battery) may cause sparks. This is normal. After the two of them get to equal voltage, the sparks will disappear.

Even if the peak current of a pulse load, such as motor, bulb, DC-DC or DC-AC converter module, does not exceed the rated current of the power supply, it will also cause voltage drop or instability to the output.

A basic solution is to connect a inductor in serial between the power supply and the load. Or, choose a power supply with higher rated current.

If the pulse circuit has a small pulse width or low peak current, another solution is to connect a capacitor with large capacity. A reference to choose capacity of a capacity is: 1000uF capacity to a 1A current.

When the power supply is connected to a load that will cause reverse polarity current to the power supply output, the output voltage will increase, because the power supply cannot absorb the reverse polarity current from the load.

A solution is to connect a diode in serial between the output terminal and the load; at the same time, connect a discharge resistor in parallel to the load to absorb the reverse polarity current. When the reverse polarity current is a peak surge, connect the large electrolytic capacitor in parallel to the two ends of the load.

Get In Touch

Welcome to discuss your purchasing requirements with our customer service.

    Why Choose Us

    Rich Experience

    With years of industry knowledge, we bring unparalleled expertise to every project.

    Quality Control

    Our rigorous standards ensure top-notch quality in all our products.

    Respect Life

    We prioritize safety and environmental sustainability in everything we do.

    Unlimited Innovation

    Constantly striving for new and improved solutions, we never stop innovating.

    Customization Service

    Tailoring our services to your unique needs, we ensure complete satisfaction.

    Our Service

    Experience excellence with our dedicated support and customer-focused approach.

    en_USEnglish