- With years of industry knowledge, we bring unparalleled expertise to every project.
- Our rigorous standards ensure top-notch quality in all our products.
- Constantly striving for new and improved solutions, we never stop innovating.
- Tailoring our services to your unique needs, we ensure complete satisfaction.
- Experience excellence with our dedicated support and customer-focused approach.
PCH 4kW 4000V 1A DC High Voltage Power Source 1000V 4A 2000V 2A to 8kV 12kV
PCH 4kW 4000V 1A DC High Voltage Power Source 1000V 4A 2000V 2A to 8kV 12kV
- 4kW DC High Voltage Power Source 1000V 4A 2000V 2A to 8kV 12kV
- Typical ratings: 1000V 4A, 2000V 2A, 4000V 1A, 8kV 0.5A and 10kV 0.4A
- Positive polarity 1000V to 12kV
- Optional negative polarity -1000V to -12kV
- Low ripple 0.1%FS
- High power density in 2U full rack design
- List mode function, Auto Run function
- No overshoot during startup
- Soft start by hardware, and adjustable voltage rise time by software
- Preset voltage and current
- Remote ON/OFF control
- Multiple protections: OVP, OTP, ACF and current limit protections
- Standard interface: RS232 & RS485, support ModBus-RTU commands
- Data record and export through PC control software
- Hot keys for data save and recall on PC control software
- Optional analog interface for control and feedback; LAN interface
Twintex PCH 4kW series DC high voltage power sources are available in positive or negative polarities, with voltage ratings from 1000V to 12kV in 12 different standard configurations. Custom configuration can be finalized according to specific test needs.
Utilizing ZVZCS PWM technology, the PCH 4kW DC high voltage power sources feature high power density and high reliability. Its functions and features are accessible and configurable via front panel operation or RS232 & RS485 remote control.
Built in 2U rack mount, it is convenient to integrate the 4kW DC high voltage power sources to ATE system for semiconductor processing, capacitor charging, high power RF transmitter testing, etc.
Hot models:
PCH4000-10H: 1000V 4A DC High Voltage Power Source
PCH4000-20H: 2000V 2A DC High Voltage Power Source
PCH4000-40H: 4000V 1A DC High Voltage Power Source
PCH4000-80H: 8kV 0.5A DC High Voltage Power Source
PCH4000-100H: 10kV 0.4A DC High Voltage Power Source

Product Parameters
Programmable High Voltage DC Power Supply 4kW 5kW
| Model | Rated Output | Model | Rated Output | |||||
| V | A | W | V | A | W | |||
| PCH4000-10H | 1kV | 4000mA | 4kW | PCH5000-10H | 1kV | 5000mA | 5kW | |
| PCH4000-10HN | -1kV | 4000mA | 4kW | PCH5000-10HN | -1kV | 5000mA | 5kW | |
| PCH4000-12H | 1.2kV | 3333mA | 4kW | PCH5000-12H | 1.2kV | 4166mA | 5kW | |
| PCH4000-12HN | -1.2kV | 3333mA | 4kW | PCH5000-12HN | -1.2kV | 4166mA | 5kW | |
| PCH4000-15H | 1.5kV | 2666mA | 4kW | PCH5000-15H | 1.5kV | 3333mA | 5kW | |
| PCH4000-15HN | -1.5kV | 2666mA | 4kW | PCH5000-15HN | -1.5kV | 3333mA | 5kW | |
| PCH4000-20H | 2kV | 2000mA | 4kW | PCH5000-20H | 2kV | 2500mA | 5kW | |
| PCH4000-20HN | -2kV | 2000mA | 4kW | PCH5000-20HN | -2kV | 2500mA | 5kW | |
| PCH4000-30H | 3kV | 1333mA | 4kW | PCH5000-30H | 3kV | 1666mA | 5kW | |
| PCH4000-30HN | -3kV | 1333mA | 4kW | PCH5000-30HN | -3kV | 1666mA | 5kW | |
| PCH4000-40H | 4kV | 1000mA | 4kW | PCH5000-40H | 4kV | 1250mA | 5kW | |
| PCH4000-40HN | -4kV | 1000mA | 4kW | PCH5000-40HN | -4kV | 1250mA | 5kW | |
| PCH4000-50H | 5kV | 800mA | 4kW | PCH5000-50H | 5kV | 1000mA | 5kW | |
| PCH4000-50HN | -5kV | 800mA | 4kW | PCH5000-50HN | -5kV | 1000mA | 5kW | |
| PCH4000-60H | 6kV | 666mA | 4kW | PCH5000-60H | 6kV | 833mA | 5kW | |
| PCH4000-60HN | -6kV | 666mA | 4kW | PCH5000-60HN | -6kV | 833mA | 5kW | |
| PCH4000-80H | 8kV | 500mA | 4kW | PCH5000-80H | 8kV | 625mA | 5kW | |
| PCH4000-80HN | -8kV | 500mA | 4kW | PCH5000-80HN | -8kV | 625mA | 5kW | |
| PCH4000-100H | 10kV | 400mA | 4kW | PCH5000-100H | 10kV | 500mA | 5kW | |
| PCH4000-100HN | -10kV | 400mA | 4kW | PCH5000-100HN | -10kV | 500mA | 5kW | |
| PCH4000-120H | 12kV | 333mA | 4kW | PCH5000-120H | 12kV | 416mA | 5kW | |
| PCH4000-120HN | -12kV | 333mA | 4kW | PCH5000-120HN | -12kV | 416mA | 5kW | |
| Weight | 14kg (2U), 19kg (3U) | |||||||
| Dimensions | 482.6Wx88Hx533D mm (2U-L) | |||||||
| AC Input | 3φ4W (L1, L2, L3, PE), 380V±10% 47~63Hz (at default) 1φ3W (L, N, PE), 220V±10% 47~63Hz (at request for 1kV to 8kV models, cabinet size changed to 3U) | |||||||
For the purpose of product improvement, specifications are subject to change without prior notice.
Why Choose Us.
Frequently Asked Questions
A DC power supply is to supply voltage and current in constant voltage (CV) or constant current (CC) mode within the rated output range. Such working characteristics is called a constant voltage/constant current automatic cross-over type. This permits continuous transition from constant current to constant voltage modes in response to the load change. The intersection of constant voltage and constant current modes is called the crossover point. Below figure shows the relationship between this crossover point and the load.

In CV mode, a regulated output voltage is provided. The output voltage remains constant as the load increases while the output current changes in response to the load changes, up till the present current limit point is reached. At that point, the output current becomes constant and the output voltage drops in proportion to the further increases in load.
Similarly, in CC mode, crossover from the CC to CV mode automatically occurs from a decrease in the load. A regulated output current is provided. The output current remains constant as the load decreases while the output voltage changes in response to the load changes.
A power supply with CV and CC operation mode can be operated in only one mode according to load situation. The power supply is in CV mode when the actual load is over the preset load capacity; and the power supply is in CC mode when the actual load is below the preset load capacity.
When the power supply is connected to a big capacitive load, it always causes increase to the output voltage in a power supply. The output voltage may make fast increase to the Over Voltage Protection point. It may also cause slow decrease when the output voltage is turned down.
To solve this problem, connect a power resistor in parallel to the output terminals of the power supply; at the same time, connect a diode in serial between output terminals and the load.

When an inductive load is connected to the power supply, it will cause a reverse polarity induction electric motive force when the power supply is turned on or off, or when preset the output voltage. The pulse noise caused by an inductive load will also affect the power supply, especially when the pulse noise has the same polarity with the output of power supply.
To avoid effect or damage to the power supply, connect a diode in serial between the output terminals of power supply and the load; at the same time, connect a power resistor and a capacitor in parallel to the load to make a R-C snubbed circuit, which will significantly restraint generation of the noise.

When use the power supply to charge a battery, such as accumulator and ni-mh battery, the recommended protection measures is to connect a diode between the power supply and the battery. When the output electrolytic capacitor of the power supply is charged, connecting a load (battery) may cause sparks. This is normal. After the two of them get to equal voltage, the sparks will disappear.

Even if the peak current of a pulse load, such as motor, bulb, DC-DC or DC-AC converter module, does not exceed the rated current of the power supply, it will also cause voltage drop or instability to the output.
A basic solution is to connect a inductor in serial between the power supply and the load. Or, choose a power supply with higher rated current.
If the pulse circuit has a small pulse width or low peak current, another solution is to connect a capacitor with large capacity. A reference to choose capacity of a capacity is: 1000uF capacity to a 1A current.

When the power supply is connected to a load that will cause reverse polarity current to the power supply output, the output voltage will increase, because the power supply cannot absorb the reverse polarity current from the load.
A solution is to connect a diode in serial between the output terminal and the load; at the same time, connect a discharge resistor in parallel to the load to absorb the reverse polarity current. When the reverse polarity current is a peak surge, connect the large electrolytic capacitor in parallel to the two ends of the load.

Get Quote Now!
Welcome to discuss your purchasing requirements with our customer service.
Get The
Catalogue
Document
From more than 10 years experiences in OEM & ODM services, our sales team and technical team are always available to check and discuss your requirement details.Whether you’re looking for reliable DC motors to enhance precision in your devices or powerful AC motors for robust industrial applications, we have you covered.