TFC63 Series Programmable Three Phase AC Power Source 3kVA 6kVA 10kVA 15kVA 30kVA to 800kVA

TFC63 Series Programmable Three Phase AC Power Source 3kVA 6kVA 10kVA 15kVA 30kVA to 800kVA

  • Programmable Three Phase AC Power Source
  • Output voltage: phase voltage 1~300V, line voltage 1~520V, resolution 0.1V
  • Output frequency: 45-65Hz adjustable, fixed 50Hz and 60Hz
  • Output capacity: 3kVA 6kVA 10kVA 15kVA 30kVA to 800kVA
  • Frequency stability 0.01%
  • Harmonic distortion 2%
  • Voltage stability 1%
  • Fast output key for 110/220V and 50/60Hz
  • Phase difference: 120°±2°
  • Fast transient response time 2ms
  • Multiple protections: OVP, OCP, OTP and OLP
  • Optional RS232/RS485 interface
  • Optional DC0-5V analog input for output control

TFC63 series programmable three phase AC power source ranges from 3kVA to 800kVA power. The output frequency is variable from 45Hz to 65Hz, with hot keys for 50Hz and 60Hz and 400Hz. Each phase can be connected to unbalanced load. The output voltage can be customized to 1000Vac in either two ranges (low range and high range) or single range.

Adopting PWM high frequency technology & IGBT regulation, the programmable three phase AC power source features good reliability, fast response and high efficiency. They can be used to simulate grids of different countries, widely used in laboratories, production calibration & test and military applications.

Product Parameters

TFC63 Series Three Phase AC Power Source

ModelTotal CapacityMax. CurrentAC InputN.W. (kg)G.W. (kg)Dimension (mm)
Low range @110VHigh range @220V
TFC-63033KVA9A4.5A1P 220Vac7590420W*520H*580D
TFC-63066KVA18A9A3P 380Vac150175500W*900H*680D
TFC-631010KVA30A15A3P 380Vac170200500W*900H*680D
TFC-631515KVA46A23A3P 380Vac200240500W*900H*680D
TFC-632020KVA60A30A3P 380Vac260300590W*1100H*800D
TFC-633030KVA90A45A3P 380Vac300360590W*1100H*800D
TFC-634545KVA136A68A3P 380Vac420500720W*1220H*1080D
TFC-636060KVA180A90A3P 380Vac500580720W*1220H*1080D
TFC-637575KVA226A113A3P 380Vac530610750W*1300H*1382D
TFC-639090KVA272A136A3P 380Vac650730750W*1300H*1382D
TFC-63100100KVA303A151A3P 380Vac700820750W*1300H*1382D
TFC-63120120KVA364A182A3P 380Vac8009001380W*1450H*870D
TFC-63150150KVA454A227A3P 380Vac100011001380W*1450H*870D
TFC-63180180KVA546A273A3P 380Vac120013202100W*1650H*1350D
TFC-63200200KVA606A303A3P 380Vac140015202100W*1650H*1350D
TFC-63250250KVA757A378A3P 380Vac150016202100W*1650H*1350D
TFC-63300300KVA909A455A3P 380Vac185019702600W*1800H*1550D
TFC-63450450KV1363A681A3P 380Vac220023502600W*1800H*1550D
More models are available at request.

For the purpose of product improvement, specifications are subject to change without prior notice.

Why Choose Us.

  • With years of industry knowledge, we bring unparalleled expertise to every project.
  • Our rigorous standards ensure top-notch quality in all our products.
  • Constantly striving for new and improved solutions, we never stop innovating.
  • Tailoring our services to your unique needs, we ensure complete satisfaction.
  • Experience excellence with our dedicated support and customer-focused approach.

Frequently Asked Questions

A DC power supply is to supply voltage and current in constant voltage (CV) or constant current (CC) mode within the rated output range. Such working characteristics is called a constant voltage/constant current automatic cross-over type. This permits continuous transition from constant current to constant voltage modes in response to the load change. The intersection of constant voltage and constant current modes is called the crossover point. Below figure shows the relationship between this crossover point and the load.

In CV mode, a regulated output voltage is provided. The output voltage remains constant as the load increases while the output current changes in response to the load changes, up till the present current limit point is reached. At that point, the output current becomes constant and the output voltage drops in proportion to the further increases in load.

Similarly, in CC mode, crossover from the CC to CV mode automatically occurs from a decrease in the load. A regulated output current is provided. The output current remains constant as the load decreases while the output voltage changes in response to the load changes.

A power supply with CV and CC operation mode can be operated in only one mode according to load situation. The power supply is in CV mode when the actual load is over the preset load capacity; and the power supply is in CC mode when the actual load is below the preset load capacity.

When the power supply is connected to a big capacitive load, it always causes increase to the output voltage in a power supply. The output voltage may make fast increase to the Over Voltage Protection point. It may also cause slow decrease when the output voltage is turned down.

To solve this problem, connect a power resistor in parallel to the output terminals of the power supply; at the same time, connect a diode in serial between output terminals and the load.

When an inductive load is connected to the power supply, it will cause a reverse polarity induction electric motive force when the power supply is turned on or off, or when preset the output voltage. The pulse noise caused by an inductive load will also affect the power supply, especially when the pulse noise has the same polarity with the output of power supply.

To avoid effect or damage to the power supply, connect a diode in serial between the output terminals of power supply and the load; at the same time, connect a power resistor and a capacitor in parallel to the load to make a R-C snubbed circuit, which will significantly restraint generation of the noise.

When use the power supply to charge a battery, such as accumulator and ni-mh battery, the recommended protection measures is to connect a diode between the power supply and the battery. When the output electrolytic capacitor of the power supply is charged, connecting a load (battery) may cause sparks. This is normal. After the two of them get to equal voltage, the sparks will disappear.

Even if the peak current of a pulse load, such as motor, bulb, DC-DC or DC-AC converter module, does not exceed the rated current of the power supply, it will also cause voltage drop or instability to the output.

A basic solution is to connect a inductor in serial between the power supply and the load. Or, choose a power supply with higher rated current.

If the pulse circuit has a small pulse width or low peak current, another solution is to connect a capacitor with large capacity. A reference to choose capacity of a capacity is: 1000uF capacity to a 1A current.

When the power supply is connected to a load that will cause reverse polarity current to the power supply output, the output voltage will increase, because the power supply cannot absorb the reverse polarity current from the load.

A solution is to connect a diode in serial between the output terminal and the load; at the same time, connect a discharge resistor in parallel to the load to absorb the reverse polarity current. When the reverse polarity current is a peak surge, connect the large electrolytic capacitor in parallel to the two ends of the load.

Get Quote Now!

Welcome to discuss your purchasing requirements with our customer service.

    Get The
    Catalogue
    Document

    From more than 10 years experiences in OEM & ODM services, our sales team and technical team are always available to check and discuss your requirement details.Whether you’re looking for reliable DC motors to enhance precision in your devices or powerful AC motors for robust industrial applications, we have you covered.

    en_USEnglish